Mini-Split Operating Cost Calculator

Enter how much heat you need in a season, your unit’s HSPF2 and your fuel prices. The calculator shows a yearly heating cost for a mini-split next to electric baseboard, propane, heating oil and natural gas. It runs in your browser; nothing is stored.

This page may contain affiliate links. If you buy through them, we may earn a commission at no extra cost to you. Read our affiliate disclosure.

Mini-split operating cost calculator

1. Heat you need and your unit

Example value. Use a load calculation or past fuel bills (gallons × Btu per gallon × furnace efficiency).
From the spec sheet. Example: MRCOOL DIY 5th Gen 12k, Region V (colder climates) = 7.6; Region IV = 10.2.

2. Electricity

From your state; type over it with the rate on your bill.

3. Other fuels to compare (example prices: replace with yours)

Your estimate per heating season

3,412 Btu per kWh (EIA).

91,452 Btu per gallon (EIA).

138,500 Btu per gallon (EIA).

100,000 Btu per therm (EIA).

Check heat needed: it can’t be below 0. Negative values are treated as 0.

Check HSPF2: enter the rating from the spec sheet (1 or more) to see the mini-split cost.

Check efficiency: enter the appliance’s rated efficiency (above 0%) to see that fuel’s cost.

How this is calculated

Mini-split kWh = heat needed (Btu) ÷ HSPF2 ÷ 1,000. Other fuels: heat needed ÷ (Btu per unit × efficiency) × price. Conversion factors and state rates: U.S. EIA. HSPF2 is a seasonal rating under test conditions, so real costs vary with climate, installation and thermostat settings. Estimates only.

How the math works

  • Mini-split kWh = heat needed (Btu) ÷ HSPF2 ÷ 1,000. HSPF2 is Btu of heat per watt-hour.
  • Baseboard kWh = heat needed ÷ 3,412 Btu per kWh (EIA).
  • Propane gallons = heat needed ÷ (91,452 Btu × appliance efficiency); heating oil uses 138,500 Btu per gallon; natural gas uses 100,000 Btu per therm (EIA).
  • State electricity rates are EIA residential averages for July 2026 (EIA Table 5.6.A). Use the rate on your bill if you know it.

Fuel prices and heat needed are example defaults; replace them with your own. HSPF2 is a seasonal rating under test conditions, so real costs vary with climate and installation. See the operating cost guide for a worked example.

Comparing models? Use the HSPF2 on each unit’s AHRI certificate (how to read one) rather than a marketing figure. Systems to compare: Compare mini-splits at HVACDirect → · Shop ENERGY STAR mini-splits on Amazon →